Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Int J Cardiol ; 345: 29-35, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34610357

RESUMO

BACKGROUND: Isolated atrial fibrillation can cause mitral regurgitation (MR) in patients with normal left ventricular systolic function and no organic disease of the mitral valve. Little information is available regarding outcomes of Mitraclip in patients with atrial functional mitral regurgitation (AFMR). We aimed to evaluate 12-month clinical and echocardiographic outcomes of transcatheter mitral valve repair (TMVR) with MitraClip in patients with AFMR compared to those with ventricular functional or degenerative/mixed MR. METHODS: Registry-based analysis of all consecutive patients who underwent TMVR and were included in the Spanish Registry of Mitraclip. Changes in MR and NYHA functional class, and a combined endpoint including all-cause mortality and hospitalizations due to heart failure were the main outcomes. RESULTS: Overall, 1074 (69.1% male, 73.3 ± 10.2 years-old) patients were analyzed in this report. 48 patients (4.5%) presented AFMR. AFMR was significantly reduced after TMVR, with a procedural success rate of 91.7%, and this reduction persisted at 12-month (p < 0.001). Patients with AFMR showed a significant functional improvement at 6- and 12-month follow-up in our series (baseline: NYHA III 70.8% IV 18.8% vs. 1-year: NYHA III 21.7% IV 0%; p < 0.001). The probability of survival free of readmission for heart failure and all-cause mortality within the first year after TMVR was 74.9%. Procedural and clinical outcomes, as well as recurrent rates of MR were similar acutely and at 1-year compared to other etiologies. CONCLUSION: TMVR in patients with AFMR showed no significant differences compared to ventricular functional or degenerative/mixed MR regarding MR reduction or clinical outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Ecocardiografia , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
2.
J Clin Med ; 10(5)2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33801311

RESUMO

BACKGROUND: Transcatheter mitral valve repair (TMVR) is an effective therapy for high-risk patients with severe mitral regurgitation (MR) but heart failure (HF) readmissions and death remain substantial on mid-term follow-up. Recently, right ventricular (RV) to pulmonary arterial (PA) coupling has emerged as a relevant prognostic predictor in HF. In this study, we aimed to assess the prognostic value of tricuspid annular plane systolic excursion (TAPSE) to PA systolic pressure (PASP) ratio as a non-invasive measure of RV-to-PA coupling in patients undergoing TMVR with MitraClip (Abbott, CA, USA). METHODS: Multicentre registry including 228 consecutive patients that underwent successful TMVR with MitraClip. The sample was divided in two groups according to TAPSE/PASP median value: 0.35. The primary combined endpoint encompassed HF readmissions and all-cause mortality. RESULTS: Mean age was 72.5 ± 11.5 years and 154 (67.5%) patients were male. HF readmissions and all-cause mortality were more frequent in patients with TAPSE/PASP ≤ 0.35: Log-Rank 8.844, p = 0.003. On Cox regression, TAPSE/PASP emerged as a prognostic predictor of the primary combined endpoint, together with STS-Score. TAPSE/PASP was a better prognostic predictor than either TAPSE or PASP separately. CONCLUSIONS: TAPSE/PASP ratio appears as a novel prognostic predictor in patients undergoing MitraClip implantation that might improve risk stratification and candidate selection.

3.
J Clin Med ; 10(4)2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33673247

RESUMO

BACKGROUND AND AIM: Recent randomized data comparing percutaneous mitral valve repair (PMVR) versus optimal medical treatment in patients with functional MR (FMR) seemed to highlight the importance of the learning curve not only for procedural outcomes but also for patient selection. The aim of the study was to compare a contemporary series of patients undergoing PMVR using a second-generation Mitraclip device (Mitraclip NT) with previous cohorts treated with a first-generation system. METHODS: This multicenter study collected individual data from 18 centers between 2012 and 2017. The cohort was divided into three groups according to the use of the first-generation Mitraclip during the first (control-1) or second half (control-2) or the Mitraclip NT system. RESULTS: A total of 545 consecutive patients were included in the study. Among all, 182 (33.3%), 183 (33.3%), and 180 (33.3%) patients underwent mitral repair in the control-1, control-2, and NT cohorts, respectively. Procedural success was achieved in 93.3% of patients without differences between groups. Major adverse events did not statistically differ among groups, but there was a higher rate of pericardial effusion in the control-1 group (4.3%, 0.6%, and 2.6%, respectively; p = 0.025). The composite endpoint of death, surgery, and admission for congestive heart failure (CHF) at 12 months was lower in the NT group (23.5% in control-1, 22.5% in control-2, and 8.3% in the NT group; p = 0.032). CONCLUSIONS: The present paper shows that contemporary clinical outcomes of patients undergoing PMVR with the Mitraclip system have improved over time.

4.
Rev. esp. cardiol. (Ed. impr.) ; 73(8): 643-651, ago. 2020. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-198250

RESUMO

INTRODUCCIÓN Y OBJETIVOS: La reparación de la válvula mitral transcatéter (RVMT) con el sistema MitraClip es un tratamiento para los pacientes con insuficiencia mitral (IM) grave de alto riesgo quirúrgico. El objetivo principal fue analizar los resultados del RVMT en pacientes con IM grave, según la etiología. MÉTODOS: Estudio observacional, prospectivo y multicéntrico con inclusión de pacientes consecutivos. El objetivo primario fue el combinado de mortalidad por todas las causas y reingresos hospitalarios por insuficiencia cardiaca al año. Se compararon las características clínicas y del procedimiento y los eventos para cada grupo de IM. Se realizó un análisis multivariable para determinar las variables asociadas con el objetivo primario. RESULTADOS: Se incluyó a 558 pacientes; 364 (65,2%) tenían etiología funcional; 111 (19,9%), degenerativa, y 83 (14,9%), mixta. La media de edad fue 72,8±11,1 años y eran varones el 70,3%. Respecto al objetivo primario, hubo 95 (17%) eventos en toda la serie. No hubo diferencias significativas entre los 3 grupos en el número de eventos del objetivo primario: 11 (11,3%) en la IM degenerativa, 71 (21,3%) en la funcional y 13 (18,1%) en la mixta (p = 0,101). Los predictores independientes fueron la clase funcional (p = 0,029), la revascularización quirúrgica previa (p = 0,031), el EuroSCORE II (p = 0,003), la diabetes mellitus (p = 0,037) y la fracción de eyección del ventrículo izquierdo (p = 0,015). CONCLUSIONES: Este trabajo confirma con datos de la práctica clínica la seguridad y la eficacia de la RVMT independientemente de la etiología de la IM y se documentan los principales factores asociados con el pronóstico durante el primer año de seguimiento


INTRODUCTION AND OBJECTIVES: Transcatheter mitral valve repair (TMVR) with MitraClip is a therapeutic option for high surgical risk patients with severe mitral regurgitation (MR). The main objective of this study was to analyze differences in outcomes in patients with severe MR according to the cause of MR. METHODS: Observational, multicenter, and prospective study with consecutive patient inclusion. The primary endpoint was the combination of all-cause mortality and new readmissions due to heart failure after 1 year. We compared clinical and procedural characteristics and the event rate for each MR group. We performed a multivariate analysis to identify predictive variables for the primary endpoint. RESULTS: A total of 558 patients were included: 364 (65.2%) with functional etiology, 111 (19.9%) degenerative and 83 (14.9%) mixed. The mean age was 72.8±11.1 years and 70.3% of the sample were men. There were 95 (17%) events in the overall sample. No significant differences were found in the 3 groups in the number of primary outcome events: 11 (11.3%) in degenerative MR, 71 (21.3%) in functional MR, and 13 (18.1%) in mixed MR (P=.101). Independent predictors were functional class (P=.029), previous surgical revascularization (P=.031), EuroSCORE II (P=.003), diabetes mellitus (P=.037), and left ventricular ejection fraction (P=.015). CONCLUSIONS: This study confirms the safety and efficacy of TMVR with MitraClip irrespective of MR etiology in real-life data and shows the main factors related to prognosis during the first year of follow up


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Coração Auxiliar , Disfunção Ventricular Esquerda/classificação , Resultado do Tratamento , Segurança do Paciente , Índice de Gravidade de Doença , Estudos Prospectivos , Cateterismo Cardíaco/métodos , Espanha/epidemiologia
5.
Rev Esp Cardiol (Engl Ed) ; 73(8): 643-651, 2020 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31732437

RESUMO

INTRODUCTION AND OBJECTIVES: Transcatheter mitral valve repair (TMVR) with MitraClip is a therapeutic option for high surgical risk patients with severe mitral regurgitation (MR). The main objective of this study was to analyze differences in outcomes in patients with severe MR according to the cause of MR. METHODS: Observational, multicenter, and prospective study with consecutive patient inclusion. The primary endpoint was the combination of all-cause mortality and new readmissions due to heart failure after 1 year. We compared clinical and procedural characteristics and the event rate for each MR group. We performed a multivariate analysis to identify predictive variables for the primary endpoint. RESULTS: A total of 558 patients were included: 364 (65.2%) with functional etiology, 111 (19.9%) degenerative and 83 (14.9%) mixed. The mean age was 72.8±11.1 years and 70.3% of the sample were men. There were 95 (17%) events in the overall sample. No significant differences were found in the 3 groups in the number of primary outcome events: 11 (11.3%) in degenerative MR, 71 (21.3%) in functional MR, and 13 (18.1%) in mixed MR (P=.101). Independent predictors were functional class (P=.029), previous surgical revascularization (P=.031), EuroSCORE II (P=.003), diabetes mellitus (P=.037), and left ventricular ejection fraction (P=.015). CONCLUSIONS: This study confirms the safety and efficacy of TMVR with MitraClip irrespective of MR etiology in real-life data and shows the main factors related to prognosis during the first year of follow up.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
7.
Catheter Cardiovasc Interv ; 86(2): 347-52, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25545173

RESUMO

A patient with severe aortic valve disease and high surgical risk underwent Direct Flow (DF) valve implantation. Anatomical assessment (Trans-esophageal echocardiography (TEE) and CT scan) revealed a 3-leaflet aortic valve (annulus diameter 23.4 mm) that was functionally bicuspid because of complete and linearly calcified fusion of noncoronary and right cusps. The valve had severe stenosis (peak/mean gradients of 70/45 mm Hg) and moderate to severe regurgitation. A balloon valvuloplasty (semicompliant 23 mm × 45 mm balloon, 2 inflations) was performed with persistence of balloon waist. A 25 DF valve was positioned in the aortic annulus, with both rings well expanded. A mild deformity in the vertical supporting tubes was observed but considered nonrelevant because valve function (peak/mean gradients of 25/12 mm Hg respectively and no aortic regurgitation) was acceptable. Then the polymer was injected and the valve released from its attachments. Postoperative course was uneventful without clinical complications; nevertheless 3 days later Doppler peak/mean transaortic gradients were 80/45 mm Hg. These high gradients were confirmed by direct invasive measurements while CT scan documented a severe geometrical deformation of the valve cuff. Since patient was in good clinical condition, a conservative strategy was adopted. Eight months later, patient functional status had improved (NYHA class II), left ventricular dimensions decreased, left ventricular ejection fraction (LVEF) increased, and valve gradients remained unchanged; therefore surgical aortic valve replacement has been deferred until clinical indication. Such a favorable course can be explained by disappearance of aortic regurgitation. Patient anatomical and procedural features that conditioned this very rare phenomenon are discussed as well as clues to prevent it.


Assuntos
Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Idoso , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Cateterismo Cardíaco/métodos , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Desenho de Prótese , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
EuroIntervention ; 10 Suppl T: T23-31, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25256530

RESUMO

AIMS: To highlight differences between the most recent guidelines of the European Society of Cardiology (ESC) and the American College of Cardiology Foundation/American Heart Association (ACCF/AHA) on the management of ST-elevation myocardial infarction (STEMI). METHODS AND RESULTS: ESC 2012 and ACCF/AHA 2013 guidelines on the management of STEMI were systematically reviewed for consistency. Recommendations were matched, directly compared in terms of class of recommendation and level of evidence, and classified as "identical", "overlapping", or "different". Out of 32 recommendations compared, 26 recommendations (81%) were classified as identical or overlapping, and six recommendations (19%) were classified as different. Most diverging recommendations were related to minor differences in class of recommendation between the two documents. This applies to recommendations for reperfusion therapy >12 hours after symptom onset, immediate transfer of all patients after fibrinolytic therapy, rescue PCI for patients with failed fibrinolysis, and intra-aortic balloon pump use in patients with cardiogenic shock. More substantial differences were observed with respect to the type of P2Y12 inhibitor and duration of dual antiplatelet therapy. CONCLUSIONS: The majority of recommendations for the management of STEMI according to ESC and ACCF/AHA guidelines were identical or overlapping. Differences were explained by gaps in available evidence, in which case expert consensus differed between European and American guidelines due to divergence in interpretation, perception, and culture of medical practice. Systematic comparisons of European and American guidelines are valuable and indicate that interpretation of available evidence leads to agreement in the vast majority of topics. The latter is indirect support for the process of review and guideline preparation on both sides of the Atlantic.


Assuntos
Cardiologia/normas , Infarto do Miocárdio/terapia , Guias de Prática Clínica como Assunto , Terapia Trombolítica/normas , American Heart Association , Europa (Continente) , Humanos , Estados Unidos
15.
Int J Cardiol ; 162(2): 117-22, 2013 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-21636149

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) techniques have been presenting good procedural success and favorable clinical outcomes. However, optimal management of aortic valve disease in elderly patients depends on quality of life (QoL) improvement. In this study we aimed to evaluate changes in QoL in patients referred for TAVI. METHODS AND RESULTS: Prospective analysis of 74 consecutive patients (34 male), aged 81.6 ± 8 years with symptomatic severe aortic valve stenosis (AS) ineligible for conventional aortic valve replacement, referred to TAVI in one tertiary center. For the assessment of QoL, the Minnesota Living with Heart Failure Questionnaire (MLHFQ) was used before the procedure and at 6.5 months. The mortality was 9.5% at 30 days and 20.2% at 6.5 months follow-up. Fifty three (71.6%) patients completed MLHFQ at baseline and at follow-up. All patients showed good hemodynamic results and no signs of prosthesis dysfunction were observed on transthoracic echocardiography. The New York Heart Association (NYHA) class (2.9 ± 0.4 to 1.4 ± 0.7; p<0.001), and the MLHFQ scores [overall (37.0 ± 14.7 vs. 14.4 ± 10.1; p<0.001), physical dimension (23.2 ± 9.5 vs. 8.6 ± 5.9; p<0.001) and emotional dimension (5.4 ± 4.2 vs. 2.6 ± 3.0; p<0.001)] were significantly improved 6.5 months after TAVI. Patients with peripheral vascular disease (PVD) had an inferior improvement in QoL caused by a lower enhancement in physical dimension MLHFQ score (mean difference: -17.0 ± 10.2 vs. -10.1 ± 11.5; p=0.036). CONCLUSION: TAVI significantly improves symptoms and QoL in patients with severe AS and high surgical risk. Patients with PVD might be expected to have a less impressive improvement in QoL after TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/psicologia , Cateterismo Cardíaco , Estudos de Coortes , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Inquéritos e Questionários , Resultado do Tratamento
17.
Rev. esp. cardiol. (Ed. impr.) ; 64(12): 1202-1206, dic. 2011. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-93628

RESUMO

Tras el implante de prótesis percutánea aórtica CoreValve®, pueden aparecer trastornos de conducción auriculoventricular que precisan marcapasos permanente (un 40-45% de los pacientes). El objetivo de nuestro estudio es detectar si alguna variable ecocardiográfica de 2 o 3 dimensiones podría predecir la aparición de trastornos de conducción auriculoventricular. Para ello se estudió en 26 pacientes consecutivos la relación de la prótesis con el septo interventricular; 12 pacientes (46,1%) presentaron trastornos de conducción auriculoventricular tras el procedimiento. Una penetración protésica en el tracto de salida del ventrículo izquierdo > 12 mm y una superficie de contacto del stent de la prótesis con el septo interventricular en diástole > 90% se asociaron fuertemente con la aparición de trastornos de conducción auriculoventricular (87,5%; p=0,034). La superficie de contacto del stent resultó ser el único predictor independiente de dicha complicación (odds ratio=1,12; intervalo de confianza del 95%, 1,01-1,25; p=0,03). Los resultados indican que la implantación más alta de las prótesis y la reducción de la longitud del stent podrían reducir la frecuencia de esta complicación (AU)


Atrioventricular conduction disorders can appear after the implantation of percutaneous aortic CoreValve® prostheses in patients requiring permanent pacemakers (40%-45% of these patients). The aim of our study was to detect if 2- or 3-dimensional echocardiographic variables could predict the appearance of atrioventricular conduction disorders. For this purpose, the relationship of the prosthesis with the interventricular septum was studied in 26 consecutive patients. Twelve patients (46.1%) developed atrioventricular conduction disorders. A prosthetic penetration >12 mm in the left ventricular outflow tract and a contact surface >90% between the interventricular septum and the stent of the prosthesis in diastole were strongly associated with the appearance of conduction disturbances (87.5%; P=.034). The percentage of the prosthetic stent in contact with the interventricular septum in end diastole was the only independent predictor of atrioventricular conduction disorders (odds ratio=1.12; 95% confidence interval, 1.01-1.25; P=.03). The results suggest that a higher implantation of the prosthesis and a reduced stent length might decrease the incidence of this complication (AU)


Assuntos
Humanos , Masculino , Feminino , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Marca-Passo Artificial/tendências , Marca-Passo Artificial , Sistema de Condução Cardíaco , Stents , Ecocardiografia Transesofagiana , Intervalos de Confiança , Razão de Chances , Modelos Logísticos , Comunicação Interventricular , Septo Interventricular/cirurgia , Septo Interventricular
19.
Rev Esp Cardiol ; 64(12): 1202-6, 2011 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-22018685

RESUMO

Atrioventricular conduction disorders can appear after the implantation of percutaneous aortic CoreValve(®) prostheses in patients requiring permanent pacemakers (40%-45% of these patients). The aim of our study was to detect if 2- or 3-dimensional echocardiographic variables could predict the appearance of atrioventricular conduction disorders. For this purpose, the relationship of the prosthesis with the interventricular septum was studied in 26 consecutive patients. Twelve patients (46.1%) developed atrioventricular conduction disorders. A prosthetic penetration >12 mm in the left ventricular outflow tract and a contact surface >90% between the interventricular septum and the stent of the prosthesis in diastole were strongly associated with the appearance of conduction disturbances (87.5%; P=.034). The percentage of the prosthetic stent in contact with the interventricular septum in end diastole was the only independent predictor of atrioventricular conduction disorders (odds ratio=1.12; 95% confidence interval, 1.01-1.25; P=.03). The results suggest that a higher implantation of the prosthesis and a reduced stent length might decrease the incidence of this complication.


Assuntos
Valva Aórtica/cirurgia , Nó Atrioventricular/fisiopatologia , Ecocardiografia Transesofagiana , Sistema de Condução Cardíaco/fisiopatologia , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Nó Atrioventricular/diagnóstico por imagem , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Testes de Função Cardíaca , Próteses Valvulares Cardíacas , Humanos , Modelos Logísticos , Masculino , Complicações Pós-Operatórias/diagnóstico , Stents
20.
Eur J Echocardiogr ; 12(10): 790-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21865229

RESUMO

AIMS: Data regarding the effects of TAVI on LV after are scarce and conflicting results have been reported immediately after aortic valvuloplasty. This study aimed to determine the acute haemodynamic effects of transcatheter aortic valve implantation (TAVI) in left ventricle (LV) diastolic performance, immediately after aortic valvuloplasty and prosthesis deployment. METHODS AND RESULTS: Sixty-one patients with severe aortic valve stenosis, and preserved LV systolic function submitted to successful TAVI, were included. All procedures were guided through transoesophageal echocardiography, and parameters of diastolic function were evaluated before and minutes after TAVI. The mean age was 83.5±6 years and mean log EuroSCORE was 18.2±9.4. Before the procedure, all patients presented LV diastolic dysfunction. Immediately after TAVI, fewer patients presented a restrictive pattern [27 (44.3%), before the procedure, vs. 20 (34.4%), after TAVI (P=0.047)], and an increase in E wave deceleration time (211.2±75.5 vs. 252.7±102.3 cm/s, P=0.001), in E wave velocity (109.5±41.2 vs. 120.3±43.6 cm/s, P=0.025), and in isovolumetric relaxation time (83±36.5 vs. 97.1±36.0 ms, P=0.013) was observed. On multivariate analysis of covariance (ANCOVA), adjusting to LV systolic function, heart rate, blood pressure, and haematocrit values, the results remained significant. Patients referred to percutaneous approach had invasive haemodynamic data collected, showing a decrease in LV end-diastolic pressure after valve implantation [18.8±5.7 vs. 14.7±4.7, mean difference -4.1 (95% CI: -5.9; -2.9)]. Patients with a restrictive pattern immediately after TAVI presented a smaller decrease in LV end diastolic pressure (-3.3±4.7) than those with diastolic dysfunction grade I or II (-9.5±4.7; P=0.017). CONCLUSION: This is the first study describing LV diastolic performance during TAVI. Our results show improvement in diastolic function parameters in patients with preserved LV systolic function, immediately after successful TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Disfunção Ventricular Esquerda/cirurgia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco , Diástole , Ecocardiografia Transesofagiana , Humanos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...